The first experience in normothermic ex vivo kidney perfusion (case report)
https://doi.org/10.15825/1995-1191-2024-4-171-177
Abstract
Objective: to assess if normothermic ex vivo machine perfusion (NMP) of a kidney from an expanded criteria donor (ECD) is feasible and safe.
Materials and methods. NMP of the right kidney from an ECD was performed on a device developed at Botkin Hospital. A solution based on donor’s blood with the addition of Ringer’s lactate solution and human albumin was used for perfusion. The temperature in the circuit was maintained at 37 °C. Perfusion lasted for 203 minutes, after which the renal resistive index was almost halved from 0.33 to 0.16. 120 ml of urine was obtained.
Results. The right kidney was successfully transplanted after perfusion. There was immediate function of the right renal graft in the postoperative period. The recipient’s serum creatinine level was 530 μmol/L on day 1 following transplantation and 170 μmol/L on day 14 of discharge. The left kidney was preserved by static cold storage and further transplanted to the recipient.
Conclusion. The use of NMP to preserve grafts obtained from ECDs is safe and feasible in clinical practice. Further studies are required to determine the clear indications for its use and to formulate an optimal procedure for its implementation.
About the Authors
A. V. ShabuninRussian Federation
Moscow
M. G. Minina
Russian Federation
Moscow
P. A. Drozdov
Russian Federation
Moscow
V. M. Sevostyanov
Russian Federation
Moscow
N. V. Grudinin
Russian Federation
Moscow
V. K. Bogdanov
Russian Federation
Moscow
D. A. Bankeev
Moscow
E. A. Tenchurina
Russian Federation
Elmira Tenchurina
5, Vtoroy Botkinskiy proezd, Moscow, 125284
Phone: (967) 113-87-64
References
1. Lewis A, Koukoura A, Tsianos GI, Gargavanis AA, Nielsen AA, Vassiliadis E. Organ donation in the US and Europe: the supply vs demand imbalance. Transplant Rev (Orlando). 2021 Apr; 35 (2): 100585.
2. Summers DM, Watson CJ, Pettigrew GJ, Johnson RJ, Collett D, Neuberger JM, Bradley JA. Kidney donation after circulatory death (DCD): state of the art. Kidney Int. 2015 Aug; 88 (2): 241–249.
3. Port FK, Bragg-Gresham JL, Metzger RA, Dykstra DM, Gillespie BW, Young EW et al. Donor characteristics associated with reduced graft survival: an approach to expanding the pool of kidney donors. Transplantation. 2002 Nov 15; 74 (9): 1281–1286.
4. Van’t Hoff MJH. Etudes de dynamique chimique. Recueil des Travaux Chimiques des Pays-Bas. 2010; 3 (10): 333–336.
5. Kalogeris T, Baines CP, Krenz M, Korthuis RJ. Ischemia/ reperfusion. Compr Physiol. 2016 Dec 6; 7 (1): 113–170.
6. Summers DM, Johnson RJ, Hudson A, Collett D, Watson CJ, Bradley JA. Effect of donor age and cold storage time on outcome in recipients of kidneys donated after circulatory death in the UK: a cohort study. Lancet. 2013 Mar 2; 381 (9868): 727–734.
7. Collins MG, Chang SH, Russ GR, McDonald SP. Outcomes of transplantation using kidneys from donors meeting expanded criteria in Australia and New Zeal- and, 1991 to 2005. Transplantation. 2009 Apr 27; 87 (8): 1201–1209.
8. Fraser SM, Rajasundaram R, Aldouri A, Farid S, MorrisStiff G, Baker R et al. Acceptable outcome after kidney transplantation using «expanded criteria donor» grafts. Transplantation. 2010 Jan 15; 89 (1): 88–96.
9. Metzger RA, Delmonico FL, Feng S, Port FK, Wynn JJ, Merion RM. Expanded criteria donors for kidney transplantation. Am J Transplant. 2003; 3 (4): 114–125.
10. Nicholson ML, Hosgood SA. Renal transplantation after ex vivo normothermic perfusion: the first clinical study. Am J Transplant. 2013 May; 13 (5): 1246–1252.
11. Mazilescu LI, Urbanellis P, Kim SJ, Goto T, Noguchi Y, Konvalinka A et al. Normothermic Ex Vivo Kidney Perfusion for Human Kidney Transplantation: First North American Results. Transplantation. 2022 Sep 1; 106 (9): 1852–1859.
12. Cypel M, Yeung JC, Liu M, Anraku M, Chen F, Karolak W et al. Normothermic ex vivo lung perfusion in clinical lung transplantation. N Engl J Med. 2011 Apr 14; 364 (15): 1431–1440.
13. Selzner M, Goldaracena N, Echeverri J, Kaths JM, Linares I, Selzner N et al. Normothermic ex vivo liver perfusion using steen solution as perfusate for human liver transplantation: first North American results. Liver Transpl. 2016 Nov; 22 (11): 1501–1508.
Review
For citations:
Shabunin A.V., Minina M.G., Drozdov P.A., Sevostyanov V.M., Grudinin N.V., Bogdanov V.K., Bankeev D.A., Tenchurina E.A. The first experience in normothermic ex vivo kidney perfusion (case report). Russian Journal of Transplantology and Artificial Organs. 2024;26(4):171-177. https://doi.org/10.15825/1995-1191-2024-4-171-177