DIRECT EVALUATION OF OXIDATIVE STRESS AND ANTIOXIDANT DEFENSE PARAMETERS IN EXPERIMENT WITH THE AXIAL PUMP
https://doi.org/10.15825/1995-1191-2011-4-76-80
Abstract
It is established that increased parameters of oxidative stress result from an imbalance between reactive oxygen molecules and endogenous antioxidants. Oxidative stress parameters may be considered to be biomarkers of heart failure. The aim of our study was to asses oxidative stress and antioxidant system parameters in experi- mental model with the axial pump. Our study included 7 calves (the mean age 120.33 days, the mean weight 99.17 kg). We used «FORM Plus CR3000» analyzer (Callegary, Italy) and heparinized venous blood samples for the evaluation of the oxidative status (FORT test) and the total antioxidant capacity (FORD test). In healthy animals oxidative system parameters differ from those in humans (FORT – 0.42 ± 0.11 versus 1.74 ± 0.32 mmol/l H2O2; FORD/FORT – 3.92 ± 1.30 versus 1.33 ± 0.27, p < 0.05) what should be taken into consideration when interpreting the results of clinical and experimental studies. In three calves with experimental assisted circulation maximal oxidative stress values were observed on 1–3 days after the axial pump connection with the subsequent normalization of these parameters. Direct evaluation of oxidative stress parameters may be used as monitoring tool for estimation of assisted circulation adequacy in experiment (animal model).
About the Authors
N. V. KuncevichRussian Federation
G. P. Itkin
Russian Federation
E. G. Konysheva
Russian Federation
L. V. Makarova
Russian Federation
O. P. Shevchenko
Russian Federation
References
1. Иванов С.Г., Ситникова М.Ю., Шляхто Е.В. Роль ок- сидативного стресса в развитии и прогрессировании хронической сердечной недостаточности: актуаль- ность и возможность его коррекции // Кардиология СНГ. 2006. No 4. P. 267–270.
2. Иткин Г.П., Селищев С.В. Роторные насосы для ис- кусственного и вспомогательного кровообращения // Медицинская техника. 2010. No 6. C. 39–45.
3. Конышева Е.Г., Кудинов В.Л., Дозоров К.Н. и соавт. Стендовые исследования имплантируемого осево- го насоса крови // Медицинская техника. 2010. No 6. C. 23–29.
4. Кунцевич Н.В. Возможности прямой оценки напря- женности оксидативного стресса в клинической практике // Лаборатория. 2010. No1. C. 10–12.
5. Хубутия М.Ш., Шевченко О.П. Гомоцистеин при ко- ронарной болезни сердца и сердечного транспланта- та, М.: Реафарм, 2004, 272 с.
6. Шевченко О.П., Олефиренко Г.А., Червякова Н.В. Го- моцистеин. М.: Реафарм, 2002, 46 с.
7. Шевченко О.П., Орлова О.В., Шевченко А.О. Церуло- плазмин. М.: Реафарм, 2005. 46 с.
8. Abramson J.L., Hooper W.C., Jones D.P. et al. Association between novel oxidative stress markers and C-reactive protein among adults without clinical coronary heart disease. Atherosclerosis. 2005. Vol. 178. P. 115–121.
9. Amir O., Paz H., Rogovski O., Barshai M. et al. Oxi- dative stress level correlates with clinical parameters in chronic heart failure patients // Clin. Cardiol. 2009. Vol. 32. P. 199–203.
10. Azzi A. Oxidative stress: A dead end or laboratory hy- pothesis // Biochem. Biophys Res. Commun. 2007. Vol. 362. P. 230–232.
11. Finkel T. Oxidant signals and oxidative stress // Curr. Opin. Cell. Biol. 2003. Vol. 15. P. 247–254.
12. Giordano F.J. Oxygen, oxidative stress, hypoxia and heart failure // J. Clin. Invest. 2005. Vol. 115. P. 500–508.
13. Gonenc A., Hacisevki A., Griffiths H.R. et al. Free radi- cal reaction products and antioxidant capacity in beating heart coronary artery surgery compared to conventional bypass // Biochemistry. 2011. Vol. 76 (6). Р. 677–685.
14. Kapoor M.C., Ramachandran T.R. Inflammatory respon- se to cardiac surgery and strategies to overcome it // An-
15. nals of Cardiac Anaestesia. 2004. Vol. 7. Р. 113–128.
16. Kohen R., Nyska. Oxidation of biological sistems: oxida- tive stress phenomena, antioxidants, redox reactions, and methods for their quantification // Toxicol Pathol. 2002. Vol. 30. P. 620–650.
17. Palmieri B., Sblendorio V. Oxidative stress detection: what for? // Part II. Eur. Rev. Med. Pharmacol. Sci. 2007. Vol. 11 (1). P. 27–54.
18. Palmieri B., Sblendorio V. Oxidative stress tests: over- view on reliability and use // Part II. Eur. Rev. Med. Pharmacol. Sci. 2007. Vol. 11 (6). P. 383–399.
19. Song X., Throckmorton A.L., Untaroiu A. et al. Axial blood pumps. ASAIO. 2003. Vol. 49 (4). Р. 355–364.
20. Terman A., Brunk U.T. Oxidative stress, accumulation of biological «garbage» and aging. Antioxid Redox Signal. 2006. Vol. 8. P. 197–204.
21. Torri C. Oxidative Stress, Human Diseases and Biomarkers // Clinical Laboratory International. 2003. Vol. 27 (5). P. 28–29.
Review
For citations:
Kuncevich N.V., Itkin G.P., Konysheva E.G., Makarova L.V., Shevchenko O.P. DIRECT EVALUATION OF OXIDATIVE STRESS AND ANTIOXIDANT DEFENSE PARAMETERS IN EXPERIMENT WITH THE AXIAL PUMP. Russian Journal of Transplantology and Artificial Organs. 2011;13(4):76-80. (In Russ.) https://doi.org/10.15825/1995-1191-2011-4-76-80