Preview

Russian Journal of Transplantology and Artificial Organs

Advanced search

EXPERIENCE OF USE MULTIDETECTOR-ROW COMPUTED TOMOGRAPHY TO EVALUATE THE STATUS OF CORONARY ARTERIES

https://doi.org/10.15825/1995-1191-2010-3-41-47

Abstract

The aim of this article was to show possibilities, range of application and the diagnostic sensitivity 64-slice computed tomography (CT) of coronary artery in daily work of trasplantology clinic. CT coronary angiography was performed in 283 patients (190 men and 93 women; mean age 55,6 years). In 37 patients of this group CT coronary angiography was performed before any type of operation. Invasive coronary angiography performed in 45 patients after CT, has shown high diagnostic sensitivity of this technique. 

About the Authors

R. S. Muslimov
Academician V.I. Shumakov Federal Research Center of Transplantology and Artificial Organs, Moscow
Russian Federation


N. N. Abramova
Academician V.I. Shumakov Federal Research Center of Transplantology and Artificial Organs, Moscow
Russian Federation


A. A. Pokatilov
Academician V.I. Shumakov Federal Research Center of Transplantology and Artificial Organs, Moscow
Russian Federation


References

1. Мин Д.К., Кох Р., Аппельбаум Д. и др. Мультидетек- торная компьютерная томография в диагностике сердечно-сосудистых заболеваний // Международ- ный журнал интервенционной кардиоангиологии. 2005. No 8. С. 39–46.

2. Покатилов А.А. Оптимизация стентирования ствола левой коронарной артерии: Автореф. дисс. ... канд. мед. наук. М., 2009. 20 с.

3. Терновой С.К., Синицын В.Е., Гагарина Н.В. Неинва- зивная диагностика атеросклероза и кальциноза ко- ронарных артерий. М.: Атмосфера, 2003. 141 с.

4. Тютин Л.А., Ицкович И.Э., Розенгауз Е.В. Неинва- зивная визуализация коронарных артерий с помо- щью многослойной спиральной компьютерной то- мографии (МСКТ) // Мед. визуализация. 2004. No 3. С. 65–73.

5. Achenbach S., Giesler T., Dieter R. et al. Detection of Coronary Artery Stenoses by Contrast-Enhanced, Ret- rospectively Electrocardiographically-Gated, Multisli- ce Spiral Computed Tomography // Circulation 2001. Vol. 103. P. 2535–2538.

6. Bastarrika G., Lee Y. S., Huda W. et al. CT of Coro- nary Artery Disease // Radiology. November 1, 2009. Vol. 253 (2). P. 317–338.

7. Bluemke D.A, Achenbach S., Budoff M. et al. Nonin- vasive Coronary Artery Imaging: Magnetic Resonance Angiography and Multidetector Computed Tomography Angiography: A Scientific Statement From the American Heart Association Committee on Cardiovascular Imag- ing and Intervention of the Council on Cardiovascular Radiology and Intervention, and the Councils on Clinical Cardiology and Cardiovascular Disease in the Young // Circulation. July 29, 2008. Vol. 118 (5). P. 586–606.

8. Gouya H., Varenne O., Trinquart L. et al. Coronary Artery Stenosis in High-risk Patients: 64-Section CT and Coronary Angiography – Prospective Study and Analysis of Discordance // Radiology. August 1, 2009. Vol. 252 (2). P. 377–385.

9. Gottlieb I. and Lima J. A.C. Screening High-Risk Pa- tients With Computed Tomography Angiography // Cir- culation, March 11, 2008. Vol. 117 (10). P. 1318–1332.

10. Muhlenbruch G., Mahnken A.H., Das M. et al. Evalua- tion of Aortocoronary Bypass Stents with Cardiac MDCT Compared with Conventional Catheter Angiography // Am. J. Roentgenol. February 1, 2007. Vol. 188 (2). P. 361–369.

11. Oncel D., Oncel G., Tastan A. Effectiveness of Dual- Source CT Coronary Angiography for the Evaluation of Coronary Artery Disease in Patients with Atrial Fibrilla- tion: Initial Experience // Radiology, December 1, 2007. Vol. 245 (3). P. 703–711.

12. Prat-Gonzalez S., Sanz J., and Garcia M.J. Cardiac CT: Indications and Limitations // J. Nucl. Med. Technol. March 1, 2008. Vol. 36 (1). P. 18–24.

13. Raff G.L. and Goldstein J.A. Coronary Angiography by Computed Tomography: Coronary Imaging Evolves // J. Am. Coll. Cardiol. May 8, 2007. Vol. 49 (18). P. 1830– 1833.

14. Roberts W.T., Bax J.J., Davies L.C. Cardiac CT and CT coronary angiography: technology and application // Heart, June 1, 2008. Vol. 94 (6). P. 781–792.

15. Rumberger J.A., Brundage B.H., Rader D.J. et al. Elec- tron beam computed tomographic coronary calcium scanning: a review and guidelines for use in asymptoma- tic persons // Mayo Clin. Proc. 1999. Vol. 74. P. 243–252.

16. Stolzmann P., Scheffel H., Leschka S. et al. Influence of Calcifications on Diagnostic Accuracy of Coronary CT Angiography Using Prospective ECG Triggering // Am. J. Roentgenol. December 1, 2008. Vol. 191 (6). P. 1684– 1689.