<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">vtio</journal-id><journal-title-group><journal-title xml:lang="ru">Вестник трансплантологии и искусственных органов</journal-title><trans-title-group xml:lang="en"><trans-title>Russian Journal of Transplantology and Artificial Organs</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1995-1191</issn><publisher><publisher-name>Academician V.I.Shumakov National Medical Research Center of Transplantology and Artificial Organs", Ministry of Health of the Russian Federation</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.15825/1995-1191-2018-4-100-106</article-id><article-id custom-type="elpub" pub-id-type="custom">vtio-956</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Обзор литературы</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>Literature Reviews</subject></subj-group></article-categories><title-group><article-title>Высокая проницаемость мембран для гемодиализа: плюсы и минусы</article-title><trans-title-group xml:lang="en"><trans-title>High dialysis  membranes permeability: pluses and minuses</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Строков</surname><given-names>А. Г.</given-names></name><name name-style="western" xml:lang="en"><surname>Strokov</surname><given-names>A. G.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Москва</p></bio><bio xml:lang="en"><p>Moscow</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Поз</surname><given-names>Я. Л.</given-names></name><name name-style="western" xml:lang="en"><surname>Poz</surname><given-names>I. L.</given-names></name></name-alternatives><bio xml:lang="ru"><p>123182, Москва, ул. Щукинская, д. 1Тел. (916) 606-77-16</p></bio><bio xml:lang="en"><p>1, Shchukinskaya str., Moscow, 123182Tel. (916) 606-77-16</p></bio><email xlink:type="simple">dr.poz@list.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ФГБУ «Национальный медицинский исследовательский центр трансплантологии и искусственных органов имени академика В.И. Шумакова» Минздрава России</institution><country>Россия</country></aff><aff xml:lang="en"><institution>V.I. Shumakov National Medical Research Center of Transplantology and Artificial Organs of the Ministry of Healthcare of the Russian Federation</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2018</year></pub-date><pub-date pub-type="epub"><day>31</day><month>01</month><year>2019</year></pub-date><volume>20</volume><issue>4</issue><fpage>100</fpage><lpage>106</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Строков А.Г., Поз Я.Л., 2019</copyright-statement><copyright-year>2019</copyright-year><copyright-holder xml:lang="ru">Строков А.Г., Поз Я.Л.</copyright-holder><copyright-holder xml:lang="en">Strokov A.G., Poz I.L.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://journal.transpl.ru/vtio/article/view/956">https://journal.transpl.ru/vtio/article/view/956</self-uri><abstract><p>Современные технологии производства мембран для гемодиализа позволили существенно повысить их биосовместимость и проницаемость. Новые разновидности мембран – с высокой и средней точками отсечения по молекулярной массе просеивающихся веществ – позволяют эффективно удалять не только средние молекулы, такие как β2 -микроглобулин, но и более размерные молекулы. Высокая проницаемость современных диализных мембран и широкое внедрение конвективных методик сопряжены с повышенной потерей альбумина в ходе сеансов лечения. Какой уровень таких потерь можно считать приемлемым и где находится точка равновесия между преимуществами повышенного выведения уремических соединений и потенциальной опасностью избыточного просеивания альбумина – эти вопросы требуют дальнейших исследований.</p></abstract><trans-abstract xml:lang="en"><p>Up-to-date technologies have led to significant improvement of haemodialysis membranes biocompatibility and permeability. The new classes of membranes, high cut-off and middle cut-off, allow enhanced removal of middle molecules such as β2-microglobulin and even larger molecules. High membrane permeability along with the wide use of convective modalities are accompanied by increased albumin loss during dialysis. What is the acceptable upper limit for this loss and where is the right balance between the benefit of enhanced uremic substances removal and potential adverse effects of albumin deprivation are the active areas of research.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>гемодиализ</kwd><kwd>мембраны</kwd><kwd>проницаемость мембран</kwd><kwd>мембраны со средней точкой отсечения</kwd><kwd>потери альбумина</kwd></kwd-group><kwd-group xml:lang="en"><kwd>haemodialysis</kwd><kwd>membrane</kwd><kwd>membrane permeability</kwd><kwd>middle cut­off</kwd><kwd>albumin loss</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Kolff W, Berk H. The artificial kidney: a dialyzer with a great area. Acta Med Scand. 1944; 117: 121–134. PMID: 9402100.</mixed-citation><mixed-citation xml:lang="en">Kolff W, Berk H. The artificial kidney: a dialyzer with a great area. Acta Med Scand. 1944; 117: 121–134. PMID: 9402100.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Kiil F. Development of a parallel-flow artificial kidney in plastics. Acta Chir Scand. 1960; Suppl 253: 142–150. PMID: 14409028.</mixed-citation><mixed-citation xml:lang="en">Kiil F. Development of a parallel-flow artificial kidney in plastics. Acta Chir Scand. 1960; Suppl 253: 142–150. PMID: 14409028.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Lipps BJ, Stewart RD, Perkins HA, Holmes GW, McLain EA, Rolfs MR, Oja PD. The hollow fiber artificial kidney. Trans Am Soc Artif Intern Organs. 1967; 13: 200–207.</mixed-citation><mixed-citation xml:lang="en">Lipps BJ, Stewart RD, Perkins HA, Holmes GW, McLain EA, Rolfs MR, Oja PD. The hollow fiber artificial kidney. Trans Am Soc Artif Intern Organs. 1967; 13: 200–207.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Hakim RM.Clinical implications of hemodialysis membrane bioincompatibility. Kidney Int.1993; 44: 484–494. PMID: 8231020.</mixed-citation><mixed-citation xml:lang="en">Hakim RM.Clinical implications of hemodialysis membrane bioincompatibility. Kidney Int.1993; 44: 484–494. PMID: 8231020.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Clark WR, Gao D, Ronco C. Membranes for dialysis: composition, structure, and function. Contrib Nephrol. 2002; 137: 70–77. PMID: 12101993.</mixed-citation><mixed-citation xml:lang="en">Clark WR, Gao D, Ronco C. Membranes for dialysis: composition, structure, and function. Contrib Nephrol. 2002; 137: 70–77. PMID: 12101993.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Cheung AK, Rocco MV, Yan G, Leypoldt JK, Levin NW, Greene T et al. Serum beta-2 microglobulin levels predict mortality in dialysis patients: results of the HEMO study. J Am Soc Nephrol. 2006; 17 (2): 546–555. doi: 10.1681/ASN.2005020132.</mixed-citation><mixed-citation xml:lang="en">Cheung AK, Rocco MV, Yan G, Leypoldt JK, Levin NW, Greene T et al. Serum beta-2 microglobulin levels predict mortality in dialysis patients: results of the HEMO study. J Am Soc Nephrol. 2006; 17 (2): 546–555. doi: 10.1681/ASN.2005020132.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Okuno S, Ishimura E, Kohno K, Fujino­Katoh Y, Maeno Y, Yamakawa T et al. Serum β2 -microglobulin level is a significant predictor of mortality in maintenance haemodialysis patients. Nephrol Dial Transplant. 2009; 24: 571–577. doi: 10.1093/ndt/gfn521.</mixed-citation><mixed-citation xml:lang="en">Okuno S, Ishimura E, Kohno K, Fujino­Katoh Y, Maeno Y, Yamakawa T et al. Serum β2 -microglobulin level is a significant predictor of mortality in maintenance haemodialysis patients. Nephrol Dial Transplant. 2009; 24: 571–577. doi: 10.1093/ndt/gfn521.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">European Best Practice Guidelines for Haemodialysis II. 2 Haemodialysis dose quantification: middle molecules. Nephrol Dial Transplant. 2002; 17, Suppl. 7: 21–23. doi: 10.1093/ndt/17.suppl_7.21.</mixed-citation><mixed-citation xml:lang="en">European Best Practice Guidelines for Haemodialysis II. 2 Haemodialysis dose quantification: middle molecules. Nephrol Dial Transplant. 2002; 17, Suppl. 7: 21–23. doi: 10.1093/ndt/17.suppl_7.21.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Roumelioti M­E, Trietley G, Nolin TD, Ng Y­H, Xu Z, Alaini A et al. Beta-2 microglobulin clearance in highflux dialysis and convective dialysis modalities: a metaanalysis of published studies. Nephrol Dial Transplant. 2018; 33: 1025–1039. doi: 10.1093/ndt/gfx311.</mixed-citation><mixed-citation xml:lang="en">Roumelioti M­E, Trietley G, Nolin TD, Ng Y­H, Xu Z, Alaini A et al. Beta-2 microglobulin clearance in highflux dialysis and convective dialysis modalities: a metaanalysis of published studies. Nephrol Dial Transplant. 2018; 33: 1025–1039. doi: 10.1093/ndt/gfx311.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Campistol JM., Torregrosa JV, Ponz E, Fenollosa B. β2 -microglobulin removal by hemodialysis polymethylmetacrylate membranes. Contrib Nephrol. 1998; 125: 76–85. PMID: 9895432.</mixed-citation><mixed-citation xml:lang="en">Campistol JM., Torregrosa JV, Ponz E, Fenollosa B. β2 -microglobulin removal by hemodialysis polymethylmetacrylate membranes. Contrib Nephrol. 1998; 125: 76–85. PMID: 9895432.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Tattersall JE, Ward RA.EUDIAL group. Online hemodiafiltration: definition, dose quantification, and safety revisited. Nephrol Dial Transplant.2013; 28: 542–550. doi: 10.1093/ndt/gfs530.</mixed-citation><mixed-citation xml:lang="en">Tattersall JE, Ward RA.EUDIAL group. Online hemodiafiltration: definition, dose quantification, and safety revisited. Nephrol Dial Transplant.2013; 28: 542–550. doi: 10.1093/ndt/gfs530.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Wizemann V, Lotz C, Techert F, Utholff S. On-line haemodiafiltration versus low-flux haemodialysis. A prospective randomized study. Nephrol Dial Transplant. 2000; 15: 43–48. PMID: 10737166.</mixed-citation><mixed-citation xml:lang="en">Wizemann V, Lotz C, Techert F, Utholff S. On-line haemodiafiltration versus low-flux haemodialysis. A prospective randomized study. Nephrol Dial Transplant. 2000; 15: 43–48. PMID: 10737166.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Canaud B, Barbieri C, Marcelli D, Bellocchio F, Bowry S, Mari F et al. Optimal convection volume for improving patient outcomes in an international incident dialysis cohort treated with online hemodiafiltration. Kidney Int. 2015; 88 (5): 1108–1116. doi: 10.1038/ki.2015.139.</mixed-citation><mixed-citation xml:lang="en">Canaud B, Barbieri C, Marcelli D, Bellocchio F, Bowry S, Mari F et al. Optimal convection volume for improving patient outcomes in an international incident dialysis cohort treated with online hemodiafiltration. Kidney Int. 2015; 88 (5): 1108–1116. doi: 10.1038/ki.2015.139.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Neirynck N, Vanholder R, Schepers E, Eloot S, Pletinck A, Glorieux G. An update on uremic toxins. Int Urol Nephrol.2013; 45: 139–150. doi: 10.1007/s11255-012-0258-1.</mixed-citation><mixed-citation xml:lang="en">Neirynck N, Vanholder R, Schepers E, Eloot S, Pletinck A, Glorieux G. An update on uremic toxins. Int Urol Nephrol.2013; 45: 139–150. doi: 10.1007/s11255-012-0258-1.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Boschetti­de­Fierro A, Voigt M, Storr M, Krause B. Extended characterization of a new class of membranes for blood purification: the high cut-off membranes. Int J Artif Organs. 2013; 36: 455–463. doi: 10.5301/ijao.5000220.</mixed-citation><mixed-citation xml:lang="en">Boschetti­de­Fierro A, Voigt M, Storr M, Krause B. Extended characterization of a new class of membranes for blood purification: the high cut-off membranes. Int J Artif Organs. 2013; 36: 455–463. doi: 10.5301/ijao.5000220.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Boschetti­de­Fierro A, Voigt M, Storr M, Krause B. MCO Membranes: Enhanced Selectivity in High-Flux Class. Sci Rep. 2015; 5: 18448. doi: 10.1038/srep18448.</mixed-citation><mixed-citation xml:lang="en">Boschetti­de­Fierro A, Voigt M, Storr M, Krause B. MCO Membranes: Enhanced Selectivity in High-Flux Class. Sci Rep. 2015; 5: 18448. doi: 10.1038/srep18448.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Kirsch AH, Lyko R, Nilsson LG, Beck W, Amdahl M, Lechner P et al. Performance of hemodialysis with novel medium cut-off dialyzers. Nephrol Dial Transplant. 2017; 32 (1): 165–172. doi: 10.1093/ndt/gfw310.</mixed-citation><mixed-citation xml:lang="en">Kirsch AH, Lyko R, Nilsson LG, Beck W, Amdahl M, Lechner P et al. Performance of hemodialysis with novel medium cut-off dialyzers. Nephrol Dial Transplant. 2017; 32 (1): 165–172. doi: 10.1093/ndt/gfw310.</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Zickler D, Schindler R, Willy K, Martus P, Pawlak M, Storr M et al. Medium Cut-Off (MCO) Membranes Reduce Inflammation in Chronic Dialysis Patients – A Randomized Controlled Clinical Trial. PLoS One. 2017 Jan 13; 12 (1): e0169024. doi: 10.1371/journal.pone.0169024.</mixed-citation><mixed-citation xml:lang="en">Zickler D, Schindler R, Willy K, Martus P, Pawlak M, Storr M et al. Medium Cut-Off (MCO) Membranes Reduce Inflammation in Chronic Dialysis Patients – A Randomized Controlled Clinical Trial. PLoS One. 2017 Jan 13; 12 (1): e0169024. doi: 10.1371/journal.pone.0169024.</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Fiore GB, Guadagni G, Lupi A, Ricci Z, Ronco C. A new semiempirical mathematical model for prediction of internal filtration in hollow fiber hemodialyzers. Blood Purif. 2006; 24: 555–568 doi: 10.1159/000097079.</mixed-citation><mixed-citation xml:lang="en">Fiore GB, Guadagni G, Lupi A, Ricci Z, Ronco C. A new semiempirical mathematical model for prediction of internal filtration in hollow fiber hemodialyzers. Blood Purif. 2006; 24: 555–568 doi: 10.1159/000097079.</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Ronco C. The Rise of Expanded Hemodialysis. Blood Purif. 2017; 44: I–VIII. doi: 10.1159/000476012.</mixed-citation><mixed-citation xml:lang="en">Ronco C. The Rise of Expanded Hemodialysis. Blood Purif. 2017; 44: I–VIII. doi: 10.1159/000476012.</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Maduell F, Moreso F, Pons M, Ramos R, Mora­Macià J, Carreras J et al. ESHOL Study Group. High-efficiency postdilution online hemodiafiltration reduces all-cause mortality in hemodialysis patients. J Am Soc Nephrol. 2013; 24: 487–497. doi: 10.1681/ASN.2012080875.</mixed-citation><mixed-citation xml:lang="en">Maduell F, Moreso F, Pons M, Ramos R, Mora­Macià J, Carreras J et al. ESHOL Study Group. High-efficiency postdilution online hemodiafiltration reduces all-cause mortality in hemodialysis patients. J Am Soc Nephrol. 2013; 24: 487–497. doi: 10.1681/ASN.2012080875.</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Ikizler TA, Flakoll PJ, Parker RA, Hakim RM. Amino acid and albumin losses during hemodialysis. Kidney Int. 1994; 46: 830–837. PMID: 7996804.</mixed-citation><mixed-citation xml:lang="en">Ikizler TA, Flakoll PJ, Parker RA, Hakim RM. Amino acid and albumin losses during hemodialysis. Kidney Int. 1994; 46: 830–837. PMID: 7996804.</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Kaysen GA, Dubin JA, Müller HG, Mitch WE, Rosales LM, Levin NW. Relationships among inflammation nutrition and physiologic mechanisms establishing albumin levels in hemodialysis patients. Kidney Int. 2002; 61: 2240–2249. doi: 10.1046/j.1523-1755.2002.00076.x.</mixed-citation><mixed-citation xml:lang="en">Kaysen GA, Dubin JA, Müller HG, Mitch WE, Rosales LM, Levin NW. Relationships among inflammation nutrition and physiologic mechanisms establishing albumin levels in hemodialysis patients. Kidney Int. 2002; 61: 2240–2249. doi: 10.1046/j.1523-1755.2002.00076.x.</mixed-citation></citation-alternatives></ref><ref id="cit24"><label>24</label><citation-alternatives><mixed-citation xml:lang="ru">Kneis C, Beck W, Boenisch O, Klefisch F, Deppisch R, Zickler D et al. Elimination of middle-sized uremic solutes with high-flux and high-cut-off membranes: A randomized in vivostudy. Blood Purif. 2014; 36: 287–294. doi: 10.1159/000356224.</mixed-citation><mixed-citation xml:lang="en">Kneis C, Beck W, Boenisch O, Klefisch F, Deppisch R, Zickler D et al. Elimination of middle-sized uremic solutes with high-flux and high-cut-off membranes: A randomized in vivostudy. Blood Purif. 2014; 36: 287–294. doi: 10.1159/000356224.</mixed-citation></citation-alternatives></ref><ref id="cit25"><label>25</label><citation-alternatives><mixed-citation xml:lang="ru">Tsuchida K, Minakuchi J.Albumin loss under the use of the high-performance membrane. Contrib Nephrol. 2011; 173: 76–83. doi: 10.1159/000328957.</mixed-citation><mixed-citation xml:lang="en">Tsuchida K, Minakuchi J.Albumin loss under the use of the high-performance membrane. Contrib Nephrol. 2011; 173: 76–83. doi: 10.1159/000328957.</mixed-citation></citation-alternatives></ref><ref id="cit26"><label>26</label><citation-alternatives><mixed-citation xml:lang="ru">Fiedler R, Neugebauer F, Ulrich C, Wienke A, Gromann C, Storr M et al. Randomized controlled pilot study of 2 weeks’ treatment with high cutoff membrane for hemodialysis patients with elevated c-reactive protein. Artif Organs. 2012; 36: 886–893. doi: 10.1111/j.1525-1594.2012.01479.x.</mixed-citation><mixed-citation xml:lang="en">Fiedler R, Neugebauer F, Ulrich C, Wienke A, Gromann C, Storr M et al. Randomized controlled pilot study of 2 weeks’ treatment with high cutoff membrane for hemodialysis patients with elevated c-reactive protein. Artif Organs. 2012; 36: 886–893. doi: 10.1111/j.1525-1594.2012.01479.x.</mixed-citation></citation-alternatives></ref><ref id="cit27"><label>27</label><citation-alternatives><mixed-citation xml:lang="ru">Nagai K, Tsuchida K, Ishihara N, Naoto Minagawa N, Ichien G, Yamada S et al. Implications of albumin leakage for survival in maintenance hemodialysis patients: a 7-year observational study. Ther Apher Dial. 2017; 21: 378–386. doi: 10.1111/1744-9987.12526.</mixed-citation><mixed-citation xml:lang="en">Nagai K, Tsuchida K, Ishihara N, Naoto Minagawa N, Ichien G, Yamada S et al. Implications of albumin leakage for survival in maintenance hemodialysis patients: a 7-year observational study. Ther Apher Dial. 2017; 21: 378–386. doi: 10.1111/1744-9987.12526.</mixed-citation></citation-alternatives></ref><ref id="cit28"><label>28</label><citation-alternatives><mixed-citation xml:lang="ru">Ahrenholz PG, Winkler RE, Michelsen A, Lang DA, Bowry SK. Dialysis membrane-dependent removal of middle molecules during hemodiafiltration: the beta2-microglobulin/ albumin relationship. Clin Nephrol. 2004; 62: 21–28. PMID: 15267009.</mixed-citation><mixed-citation xml:lang="en">Ahrenholz PG, Winkler RE, Michelsen A, Lang DA, Bowry SK. Dialysis membrane-dependent removal of middle molecules during hemodiafiltration: the beta2-microglobulin/ albumin relationship. Clin Nephrol. 2004; 62: 21–28. PMID: 15267009.</mixed-citation></citation-alternatives></ref><ref id="cit29"><label>29</label><citation-alternatives><mixed-citation xml:lang="ru">Maduell F, Arias­Guillen M, Fontseré N, Ojeda R, Rico N, Vera M et al. Elimination of large uremic toxins by a dialyzer specifically designed for high-volume convective therapies. Blood Purif. 2014; 37: 125–130. doi: 10.1159/000358214.</mixed-citation><mixed-citation xml:lang="en">Maduell F, Arias­Guillen M, Fontseré N, Ojeda R, Rico N, Vera M et al. Elimination of large uremic toxins by a dialyzer specifically designed for high-volume convective therapies. Blood Purif. 2014; 37: 125–130. doi: 10.1159/000358214.</mixed-citation></citation-alternatives></ref><ref id="cit30"><label>30</label><citation-alternatives><mixed-citation xml:lang="ru">Fournier A, Birmele B, Francois M, Prat L, Halimi JM. Factors associated with albumin loss in post-dilution hemodiafiltration. Int J Artif Organs. 2015; 38: 76–82. doi: 10.5301/ijao.5000389.</mixed-citation><mixed-citation xml:lang="en">Fournier A, Birmele B, Francois M, Prat L, Halimi JM. Factors associated with albumin loss in post-dilution hemodiafiltration. Int J Artif Organs. 2015; 38: 76–82. doi: 10.5301/ijao.5000389.</mixed-citation></citation-alternatives></ref><ref id="cit31"><label>31</label><citation-alternatives><mixed-citation xml:lang="ru">Vega A, Quiroga B, Abad S, Aragoncillo I, Arroyo D, Panizo N et al. Albumin leakage in online hemodiafiltration, more convective transport, more losses? Ther Apher Dial. 2015; 19: 267–271. doi: 10.1111/1744-9987.12247.</mixed-citation><mixed-citation xml:lang="en">Vega A, Quiroga B, Abad S, Aragoncillo I, Arroyo D, Panizo N et al. Albumin leakage in online hemodiafiltration, more convective transport, more losses? Ther Apher Dial. 2015; 19: 267–271. doi: 10.1111/1744-9987.12247.</mixed-citation></citation-alternatives></ref><ref id="cit32"><label>32</label><citation-alternatives><mixed-citation xml:lang="ru">Gayrard N, Ficheux A, Duranton F, Guzman C, Szwarc I, Vetromile F et al. Correction: Consequences of increasing convection onto patient care and protein removal in hemodialysis. PLoS One. 2018; 13 (1): e0190761. doi: 10.1371/journal.pone.0190761.</mixed-citation><mixed-citation xml:lang="en">Gayrard N, Ficheux A, Duranton F, Guzman C, Szwarc I, Vetromile F et al. Correction: Consequences of increasing convection onto patient care and protein removal in hemodialysis. PLoS One. 2018; 13 (1): e0190761. doi: 10.1371/journal.pone.0190761.</mixed-citation></citation-alternatives></ref><ref id="cit33"><label>33</label><citation-alternatives><mixed-citation xml:lang="ru">Yamashita AC, Sakurai K. Clinical effect of pre-dilution hemodiafiltration based on the permeation of the hemodiafilter. Contrib Nephrol. 2015; 185: 1–7. doi: 10.1159/000380964.</mixed-citation><mixed-citation xml:lang="en">Yamashita AC, Sakurai K. Clinical effect of pre-dilution hemodiafiltration based on the permeation of the hemodiafilter. Contrib Nephrol. 2015; 185: 1–7. doi: 10.1159/000380964.</mixed-citation></citation-alternatives></ref><ref id="cit34"><label>34</label><citation-alternatives><mixed-citation xml:lang="ru">Potier J, Le Roy F, Faucon JP, Besselièvre T, Renaudineau E, Farquet C et al. Elevated removal of middle molecules without significant albumin loss with mixeddilution hemodiafiltration for patients unable to provide sufficient blood flow rates. Blood Purif. 2013; 36: 78–83. doi: 10.1159/000351527.</mixed-citation><mixed-citation xml:lang="en">Potier J, Le Roy F, Faucon JP, Besselièvre T, Renaudineau E, Farquet C et al. Elevated removal of middle molecules without significant albumin loss with mixeddilution hemodiafiltration for patients unable to provide sufficient blood flow rates. Blood Purif. 2013; 36: 78–83. doi: 10.1159/000351527.</mixed-citation></citation-alternatives></ref><ref id="cit35"><label>35</label><citation-alternatives><mixed-citation xml:lang="ru">Kim ST, Yamamoto C, Taoka M, Takasugi M. Programmed filtration, a new method for removing large molecules and regulating albumin leakage during hemodiafiltration treatment. Am J Kidney Dis. 2001; 38: S220–S223. PMID: 11576960.</mixed-citation><mixed-citation xml:lang="en">Kim ST, Yamamoto C, Taoka M, Takasugi M. Programmed filtration, a new method for removing large molecules and regulating albumin leakage during hemodiafiltration treatment. Am J Kidney Dis. 2001; 38: S220–S223. PMID: 11576960.</mixed-citation></citation-alternatives></ref><ref id="cit36"><label>36</label><citation-alternatives><mixed-citation xml:lang="ru">Pedrini LA, Cozzi G, Faranna P, Mercieri A, Ruggiero P, Zerbi S et al. Transmembrane pressure modulation in high-volume mixed hemodiafiltration to optimize efficiency and minimize protein loss. Kidney Int. 2006; 69: 573–579. doi: 10.1038/sj.ki.5000110.</mixed-citation><mixed-citation xml:lang="en">Pedrini LA, Cozzi G, Faranna P, Mercieri A, Ruggiero P, Zerbi S et al. Transmembrane pressure modulation in high-volume mixed hemodiafiltration to optimize efficiency and minimize protein loss. Kidney Int. 2006; 69: 573–579. doi: 10.1038/sj.ki.5000110.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
