<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">vtio</journal-id><journal-title-group><journal-title xml:lang="ru">Вестник трансплантологии и искусственных органов</journal-title><trans-title-group xml:lang="en"><trans-title>Russian Journal of Transplantology and Artificial Organs</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1995-1191</issn><publisher><publisher-name>Academician V.I.Shumakov National Medical Research Center of Transplantology and Artificial Organs", Ministry of Health of the Russian Federation</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.15825/1995-1191-2010-4-39-43</article-id><article-id custom-type="elpub" pub-id-type="custom">vtio-343</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Имплантаты и искусственные органы</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>Implants and Artificial Organs</subject></subj-group></article-categories><title-group><article-title>ОПЫТ ПРИМЕНЕНИЯ ИСКУССТВЕННЫХ КЛАПАНОВ ON-X ПРИ ПРОТЕЗИРОВАНИИ КЛАПАНОВ СЕРДЦА</article-title><trans-title-group xml:lang="en"><trans-title>EXPERIENCE WITH IN ON-X PROSTHESIS IN HEART VALVE REPLACEMENT</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Сазоненков</surname><given-names>М. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Sazonenkov</surname><given-names>M. A.</given-names></name></name-alternatives><email xlink:type="simple">sazonenkov@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Басараб</surname><given-names>Д. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Basarab</surname><given-names>D. A.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Криворот</surname><given-names>С. С.</given-names></name><name name-style="western" xml:lang="en"><surname>Krivorot</surname><given-names>S. S.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Корнелюк</surname><given-names>М. Н.</given-names></name><name name-style="western" xml:lang="en"><surname>Korneluk</surname><given-names>M. N.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Белгородская областная клиническая больница святителя Иоасафа, г. Белгород</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Regional clinical Hospital, Belgorod</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2010</year></pub-date><pub-date pub-type="epub"><day>09</day><month>06</month><year>2014</year></pub-date><volume>12</volume><issue>4</issue><issue-title>ВЕСТНИК ТРАНСПЛАНТОЛОГИИ И ИСКУССТВЕННЫХ ОРГАНОВ том XII No 4–2010</issue-title><fpage>39</fpage><lpage>43</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Сазоненков М.А., Басараб Д.А., Криворот С.С., Корнелюк М.Н., 2010</copyright-statement><copyright-year>2010</copyright-year><copyright-holder xml:lang="ru">Сазоненков М.А., Басараб Д.А., Криворот С.С., Корнелюк М.Н.</copyright-holder><copyright-holder xml:lang="en">Sazonenkov M.A., Basarab D.A., Krivorot S.S., Korneluk M.N.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://journal.transpl.ru/vtio/article/view/343">https://journal.transpl.ru/vtio/article/view/343</self-uri><abstract><p>Протез клапана сердца ON-X имеет преимущества в удобстве и безопасности имплантации, площади эффективного отверстия. Приводим результаты имплантации протеза ON-X с 2006-го по 2009 год. В этот период выполнено 792 операции с ИК. В митральную позицию имплантировано 132 протеза ON-X (91,7%). Из них с полным или частичным сохранением ЗСМК – в 80 (60,6%) и с полным сохранением обеих створок МК – в 26 (19,7%) случаях. В аортальную позицию имплантировано 76 клапанов ON-X (53,9%). Задняя аортопластика для имплантации 23-го номера потребовалась трем пациентам. В периоперационном и отдаленном послеоперационном периодах не было тромбозов и механических дисфункций. Отсутствовали реоперации по поводу высоких градиентов на протезах. Имелось 3 (1,1%) случая эмболических осложнений, связанных с погрешностью антикоагулянтной терапии. </p></abstract><trans-abstract xml:lang="en"><p>The prosthesis ON-X carcas has advantages in implantation commodity and safety, effective orifice area. We pe- sent results of this prosthesis usage during perioud of 2006–2009 years. This time 792 operations with AC were completed. In mitral position were implanted 132 (91,7%) prostheses ON-X. Of them 80 (60,6%) valves were sutured with complete or partial preservation of posterior leaflet and 26 (19,7%) valves – with total MV preser- vation. In aortic position we implanted 76 (53,9%) valves ON-X. Only 3 cases needed posterior aortoplasty for the N 23 prosthesis implantation. In perioperative and late postoperative periods we didn’t meet prostheses thrombosis or dysfunction. Reoperati- ons for high prosthesis gradients didn’t occur in postoperative period. Late postoperatively there were 3 (1,1%) cases of embolic events related to the incorrect anticoagulant treatment. </p></trans-abstract><kwd-group xml:lang="ru"><kwd>механические протезы клапанов сердца</kwd><kwd>отдаленные результаты</kwd><kwd>клапаны ОN-X.</kwd></kwd-group><kwd-group xml:lang="en"><kwd>mechanic heart valve prostheses</kwd><kwd>late results</kwd><kwd>valve ON-X.</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Akins C.W. Results with mechanical cardiac valvular prostheses // Ann Thorac. Surg. 1995. Vol. 60. P. 1836– 1844.</mixed-citation><mixed-citation xml:lang="en">Akins C.W. Results with mechanical cardiac valvular prostheses // Ann Thorac. Surg. 1995. Vol. 60. P. 1836– 1844.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Birnbaum D., Laczovics A., Heidt M., Oelert H. et al. Examination of haemolytic potential with the On-X prosthetic heart valve // J. Heart Valve Dis. 2000. Vol. 9. P. 142–145.</mixed-citation><mixed-citation xml:lang="en">Birnbaum D., Laczovics A., Heidt M., Oelert H. et al. Examination of haemolytic potential with the On-X prosthetic heart valve // J. Heart Valve Dis. 2000. Vol. 9. P. 142–145.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Burkhardt D., Hoffmann A., Vogt S. et al. Clinical evalu- ation of the St Jude mechanical prostheses: a two-year follow-up of 150 patients // J. Thorac. Cardiovasc. Surg. 1984. Vol. 88. P. 432–438.</mixed-citation><mixed-citation xml:lang="en">Burkhardt D., Hoffmann A., Vogt S. et al. Clinical evalu- ation of the St Jude mechanical prostheses: a two-year follow-up of 150 patients // J. Thorac. Cardiovasc. Surg. 1984. Vol. 88. P. 432–438.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Casarotto C. Guglielmi, Toscano G., Pistorio V. et al. Reoperations for acute prosthetic thrombosis and pan- nus: an assessment of rates, relationship and risk // Eur. J. Cardiothorac Surg. 1999. Vol. 16. P. 74–80.</mixed-citation><mixed-citation xml:lang="en">Casarotto C. Guglielmi, Toscano G., Pistorio V. et al. Reoperations for acute prosthetic thrombosis and pan- nus: an assessment of rates, relationship and risk // Eur. J. Cardiothorac Surg. 1999. Vol. 16. P. 74–80.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Chambers J., Oo L., Narracott A., Lawford P. et al. Nominal size in six bileaflet mechanical aortic valves: A comparison of orifice size and biologic equiva- lence // Thorac. Cardiovasc. Surg. 2003. Vol. 125. P. 1388–1393.</mixed-citation><mixed-citation xml:lang="en">Chambers J., Oo L., Narracott A., Lawford P. et al. Nominal size in six bileaflet mechanical aortic valves: A comparison of orifice size and biologic equiva- lence // Thorac. Cardiovasc. Surg. 2003. Vol. 125. P. 1388–1393.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Chambers J., Roxburgh J., Blauth C., O’Riordan J. et al. A randomized comparison of the MCRI On-X and Car- boMedics Top Hat bileaflet mechanical replacement aor- tic valves: Early postoperative hemodynamic function and clinical events // J. Thorac. Cardiovasc. Surg. 2005. Vol. 130. P. 759–764.</mixed-citation><mixed-citation xml:lang="en">Chambers J., Roxburgh J., Blauth C., O’Riordan J. et al. A randomized comparison of the MCRI On-X and Car- boMedics Top Hat bileaflet mechanical replacement aor- tic valves: Early postoperative hemodynamic function and clinical events // J. Thorac. Cardiovasc. Surg. 2005. Vol. 130. P. 759–764.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Fiore A., Barner H., Swartz M. et al. Mitral valve replace- ment. Randomized trial of the St. Jude and Medtronic Hall Prostheses // Ann Thorac. Surg. 1998. Vol. 66. P. 707–713.</mixed-citation><mixed-citation xml:lang="en">Fiore A., Barner H., Swartz M. et al. Mitral valve replace- ment. Randomized trial of the St. Jude and Medtronic Hall Prostheses // Ann Thorac. Surg. 1998. Vol. 66. P. 707–713.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Horstkotte D., Burckhardt D. Prosthetic valve thrombo- sis // J. Heart Valve Dis. 1995. Vol. 4. P. 141–153.</mixed-citation><mixed-citation xml:lang="en">Horstkotte D., Burckhardt D. Prosthetic valve thrombo- sis // J. Heart Valve Dis. 1995. Vol. 4. P. 141–153.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Hwang N., Reul H., Reinhard P. In vitro evaluation of the long-body On-X bileaflet heart valve // J. Heart Valve Dis. 1998. Vol. 7. P. 561–568.</mixed-citation><mixed-citation xml:lang="en">Hwang N., Reul H., Reinhard P. In vitro evaluation of the long-body On-X bileaflet heart valve // J. Heart Valve Dis. 1998. Vol. 7. P. 561–568.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Jamieson W., Miyagishima R., Grunkemeier G., Ger- mann E. et al. Bileaflet mechanical prostheses performance in mitral position // Eur. J. Cardiothorac. Surg. 1999. Vol. 15. P. 786–794.</mixed-citation><mixed-citation xml:lang="en">Jamieson W., Miyagishima R., Grunkemeier G., Ger- mann E. et al. Bileaflet mechanical prostheses performance in mitral position // Eur. J. Cardiothorac. Surg. 1999. Vol. 15. P. 786–794.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Laczkovics A., Heidt M., Oelert H., Laufer G. et al. Early experience with the On-X prosthetic heart valve //</mixed-citation><mixed-citation xml:lang="en">Laczkovics A., Heidt M., Oelert H., Laufer G. et al. Early experience with the On-X prosthetic heart valve //</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">J. Heart Valve Dis. 2001. Vol. 10. P. 94–99.</mixed-citation><mixed-citation xml:lang="en">J. Heart Valve Dis. 2001. Vol. 10. P. 94–99.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Ma L., Sines G.H. Unalloyed pyrolytic carbon for im- planted mechanical heart valves // J. Heart Valve Dis.</mixed-citation><mixed-citation xml:lang="en">Ma L., Sines G.H. Unalloyed pyrolytic carbon for im- planted mechanical heart valves // J. Heart Valve Dis.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Vol. 8. P. 578–585.</mixed-citation><mixed-citation xml:lang="en">Vol. 8. P. 578–585.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Ma L., Sines G. Fatigue behavior of a pyrolytic carbon // J. Biomed Mater Res. 2000. Vol. 51. P. 61–68.</mixed-citation><mixed-citation xml:lang="en">Ma L., Sines G. Fatigue behavior of a pyrolytic carbon // J. Biomed Mater Res. 2000. Vol. 51. P. 61–68.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Moidl R., Simon P. Wolner E and members of the On-X prosthesis heart valve trial. The On-X Prosthetic Heart Valve at Five Years // Ann Thorac. Surg. 2002. Vol. 74. S. 1312–1317.</mixed-citation><mixed-citation xml:lang="en">Moidl R., Simon P. Wolner E and members of the On-X prosthesis heart valve trial. The On-X Prosthetic Heart Valve at Five Years // Ann Thorac. Surg. 2002. Vol. 74. S. 1312–1317.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Palatianos G., Laczkovics A., Simon P., Pomar J. et al. Multicentered european study on safety and effective- ness of the On-X prosthetic heart valve: intermediate follow-up // Ann Thorac. Surg. 2007. Vol. 83. P. 40–46.</mixed-citation><mixed-citation xml:lang="en">Palatianos G., Laczkovics A., Simon P., Pomar J. et al. Multicentered european study on safety and effective- ness of the On-X prosthetic heart valve: intermediate follow-up // Ann Thorac. Surg. 2007. Vol. 83. P. 40–46.</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Saour J., Sieck J., Mamo L., Gallus A. Trial of different intensities of anticoagulation in patients with prosthetic heart valves // Engl. J. Med. 1990. Vol. 322. P. 428–432.</mixed-citation><mixed-citation xml:lang="en">Saour J., Sieck J., Mamo L., Gallus A. Trial of different intensities of anticoagulation in patients with prosthetic heart valves // Engl. J. Med. 1990. Vol. 322. P. 428–432.</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Walther T., Falk V., Tigges R., Kruger M. et al. Com- parison of On-X and SJM HP bileaflet aortic valves // J. Heart Valve Dis. 2000. Vol. 9. P. 403–407.</mixed-citation><mixed-citation xml:lang="en">Walther T., Falk V., Tigges R., Kruger M. et al. Com- parison of On-X and SJM HP bileaflet aortic valves // J. Heart Valve Dis. 2000. Vol. 9. P. 403–407.</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Wang Z., Grainger N., Chambers J. Doppler echocar- diography in normally functioning replacement heart valves: a literature review // J. Heart Valve Dis. 1995. Vol. 4. P. 591–614.</mixed-citation><mixed-citation xml:lang="en">Wang Z., Grainger N., Chambers J. Doppler echocar- diography in normally functioning replacement heart valves: a literature review // J. Heart Valve Dis. 1995. Vol. 4. P. 591–614.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
