<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">vtio</journal-id><journal-title-group><journal-title xml:lang="ru">Вестник трансплантологии и искусственных органов</journal-title><trans-title-group xml:lang="en"><trans-title>Russian Journal of Transplantology and Artificial Organs</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1995-1191</issn><publisher><publisher-name>Academician V.I.Shumakov National Medical Research Center of Transplantology and Artificial Organs", Ministry of Health of the Russian Federation</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.15825/1995-1191-2025-2-81-88</article-id><article-id custom-type="elpub" pub-id-type="custom">vtio-1942</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Трансплантация сердца и вспомогательное кровообращение</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>Heart Transplantation and Assisted Circulation</subject></subj-group></article-categories><title-group><article-title>Стендовые исследования малогабаритного осевого насоса для имплантации пациентам с малыми антропометрическими показателями</article-title><trans-title-group xml:lang="en"><trans-title>Bench studies of a small axial pump for implantation in patients with low anthropometry</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Бучнев</surname><given-names>А. С.</given-names></name><name name-style="western" xml:lang="en"><surname>Buchnev</surname><given-names>A. S.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Бучнев Александр Сергеевич, научный сотрудник Лаборатории биотехнических систем, к.б.н.</p><p>123182, Москва, ул. Щукинская, д. 1</p></bio><bio xml:lang="en"><p>Alexander S. Buchnev</p><p>1, Shchukinskaya str., Moscow, 123182</p></bio><email xlink:type="simple">labbts@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Кулешов</surname><given-names>А. П.</given-names></name><name name-style="western" xml:lang="en"><surname>Kuleshov</surname><given-names>A. P.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Москва</p></bio><bio xml:lang="en"><p>Moscow</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Дробышев</surname><given-names>А. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Drobyshev</surname><given-names>A. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Москва</p></bio><bio xml:lang="en"><p>Moscow</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Еленкин</surname><given-names>В. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Elenkin</surname><given-names>V. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Москва</p></bio><bio xml:lang="en"><p>Moscow</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Шевченко</surname><given-names>Г. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Shevchenko</surname><given-names>G. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Москва</p></bio><bio xml:lang="en"><p>Moscow</p></bio><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Грудинин</surname><given-names>Н. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Grudinin</surname><given-names>N. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Москва</p></bio><bio xml:lang="en"><p>Moscow</p></bio><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ФГБУ «Национальный медицинский исследовательский центр трансплантологии и искусственных органов имени академика В.И. Шумакова» Минздрава России</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Shumakov National Medical Research Center of Transplantology and Artificial Organs</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>ФГАОУ ВО «Российский университет дружбы народов имени Патриса Лумумбы»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Peoples’ Friendship University of Russia named after Patrice Lumumba</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2025</year></pub-date><pub-date pub-type="epub"><day>12</day><month>07</month><year>2025</year></pub-date><volume>27</volume><issue>2</issue><fpage>81</fpage><lpage>88</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Бучнев А.С., Кулешов А.П., Дробышев А.А., Еленкин В.А., Шевченко Г.А., Грудинин Н.В., 2025</copyright-statement><copyright-year>2025</copyright-year><copyright-holder xml:lang="ru">Бучнев А.С., Кулешов А.П., Дробышев А.А., Еленкин В.А., Шевченко Г.А., Грудинин Н.В.</copyright-holder><copyright-holder xml:lang="en">Buchnev A.S., Kuleshov A.P., Drobyshev A.A., Elenkin V.A., Shevchenko G.A., Grudinin N.V.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://journal.transpl.ru/vtio/article/view/1942">https://journal.transpl.ru/vtio/article/view/1942</self-uri><abstract><sec><title>Цель работы</title><p>Цель работы: провести стендовые испытания и определить рабочий диапазон скорости насоса имплан- тированной системы обхода левого желудочка сердца для дальнейшей диагностики и лечения пациентов с малыми антропометрическими показателями.</p></sec><sec><title>Материалы и методы</title><p>Материалы и методы. Исследование осевого насоса проводилось на разработанном нами гидродинамическом стенде, имитирующем сердечно-сосудистую систему и включающем в себя систему измерения и регистрации давлений и расхода, а также программное обеспечение для обработки технических и биомедицинских параметров.</p></sec><sec><title>Результаты</title><p>Результаты. Рабочий диапазон скорости вращения ротора насоса «СТРИМ КАРДИО» для достижения скорости потока в 2,5 ± 0,5 л/мин при перепаде давления 80 ± 5 мм рт. ст. будет равным 8000 ± 1000 об/мин, при этом потребляемая мощ- ность будет составлять 6,5 ± 1 Вт.</p></sec></abstract><trans-abstract xml:lang="en"><sec><title>Objective</title><p>Objective: to conduct bench tests and determine the working range of the pump speed for an implanted left ven- tricular bypass system aimed at diagnosing and treating patients with low anthropometric status.</p></sec><sec><title>Materials and methods</title><p>Materials and methods. The axial pump was investigated using a custom-developed hydrodynamic test bench simulating the cardiovascular system. The bench included systems for pressure and flow measurement and registration, along with software for processing both technical and biomedical parameters.</p></sec><sec><title>Results</title><p>Results. The operating range of the rotor speed for the STREAM CARDIO pump required to achieve a flow rate of 2.5 ± 0.5 L/min at a pressure drop of 80 ± 5 mm Hg is 8000 ± 1000 rpm, with a power consumption of 6.5 ± 1 W.</p></sec></trans-abstract><kwd-group xml:lang="ru"><kwd>сердечная недостаточность</kwd><kwd>обход левого желудочка сердца</kwd><kwd>гидродинамический стенд</kwd><kwd>расход насоса</kwd><kwd>напор насоса</kwd><kwd>осевой насос</kwd></kwd-group><kwd-group xml:lang="en"><kwd>heart failure</kwd><kwd>left ventricular bypass</kwd><kwd>hydrodynamic bench</kwd><kwd>pump flow rate</kwd><kwd>pump head</kwd><kwd>axial pump</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Hunt SA, Abraham WT, Chin MH, Feldman AM, Francis GS, Ganiats TG et al. 2009 Focused update incorporated into the ACC/AHA 2005 Guidelines for the Diagnosis and Management of Heart Failure in Adults A Report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines Developed in Collaboration With the International Society for Heart and Lung Transplantation. J Am Coll Cardiol. 2009 Apr 14; 53 (15): e1–e90.</mixed-citation><mixed-citation xml:lang="en">Hunt SA, Abraham WT, Chin MH, Feldman AM, Francis GS, Ganiats TG et al. 2009 Focused update incorporated into the ACC/AHA 2005 Guidelines for the Diagnosis and Management of Heart Failure in Adults A Report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines Developed in Collaboration With the International Society for Heart and Lung Transplantation. J Am Coll Cardiol. 2009 Apr 14; 53 (15): e1–e90.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Taylor DO, Stehlik J, Edwards LB, Aurora P, Christie JD, Dobbels F et al. Registry of the International Society for Heart and Lung Transplantation: twenty-sixth official adult heart transplant report – 2009. J Heart Lung Transplant. 2009 Oct; 28 (10): 1007–1022.</mixed-citation><mixed-citation xml:lang="en">Taylor DO, Stehlik J, Edwards LB, Aurora P, Christie JD, Dobbels F et al. Registry of the International Society for Heart and Lung Transplantation: twenty-sixth official adult heart transplant report – 2009. J Heart Lung Transplant. 2009 Oct; 28 (10): 1007–1022.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Slaughter MS, Pagani FD, Rogers JG, Miller LW, Sun B, Russell SD et al. Clinical management of continuousflow left ventricular assist devices in advanced heart failure. J Heart Lung Transplant. 2010 Apr; 29 (4 Suppl): S1–S39.</mixed-citation><mixed-citation xml:lang="en">Slaughter MS, Pagani FD, Rogers JG, Miller LW, Sun B, Russell SD et al. Clinical management of continuousflow left ventricular assist devices in advanced heart failure. J Heart Lung Transplant. 2010 Apr; 29 (4 Suppl): S1–S39.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Norman JC, Duncan JM, Frazier OH, Hallman GL, Ott DA, Reul GJ, Cooley DA. Intracorporeal (abdominal) left ventricular assist devices or partial artificial hearts: A five-year clinical experience. Arch Surg. 1981 Nov; 116 (11): 1441–1445.</mixed-citation><mixed-citation xml:lang="en">Norman JC, Duncan JM, Frazier OH, Hallman GL, Ott DA, Reul GJ, Cooley DA. Intracorporeal (abdominal) left ventricular assist devices or partial artificial hearts: A five-year clinical experience. Arch Surg. 1981 Nov; 116 (11): 1441–1445.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Liotta D, Hall CW, Henly WS, Cooley DA, Crawford ES, Debakey ME. Prolonged assisted circulation during and after cardiac or aortic surgery. prolonged partial left ventricular bypass by means of intracorporeal circulation. Am J Cardiol. 1963 Sep; 12: 399–405.</mixed-citation><mixed-citation xml:lang="en">Liotta D, Hall CW, Henly WS, Cooley DA, Crawford ES, Debakey ME. Prolonged assisted circulation during and after cardiac or aortic surgery. prolonged partial left ventricular bypass by means of intracorporeal circulation. Am J Cardiol. 1963 Sep; 12: 399–405.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">DeBakey ME. Left ventricular bypass pump for cardiac assistance. Clinical experience. Am J Cardiol. 1971 Jan; 27 (1): 3–11.</mixed-citation><mixed-citation xml:lang="en">DeBakey ME. Left ventricular bypass pump for cardiac assistance. Clinical experience. Am J Cardiol. 1971 Jan; 27 (1): 3–11.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">DeBakey ME, Kennedy JH. Mechanical circulatory support: current status. Am J Cardiol. 1971 Jan; 27 (1): 1–2.</mixed-citation><mixed-citation xml:lang="en">DeBakey ME, Kennedy JH. Mechanical circulatory support: current status. Am J Cardiol. 1971 Jan; 27 (1): 1–2.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Oz MC, Rose EA, Levin HR. Selection criteria for placement of left ventricular assist devices. Am Heart J. 1995 Jan; 129 (1): 173–177.</mixed-citation><mixed-citation xml:lang="en">Oz MC, Rose EA, Levin HR. Selection criteria for placement of left ventricular assist devices. Am Heart J. 1995 Jan; 129 (1): 173–177.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Frazier OH, Rose EA, Macmanus Q, Burton NA, Lefrak EA, Poirier VL, Dasse KA. Multicenter clinical evaluation of the HeartMate 1000 IP left ventricular assist device. Ann Thorac Surg. 1992 Jun; 53 (6): 1080–1090.</mixed-citation><mixed-citation xml:lang="en">Frazier OH, Rose EA, Macmanus Q, Burton NA, Lefrak EA, Poirier VL, Dasse KA. Multicenter clinical evaluation of the HeartMate 1000 IP left ventricular assist device. Ann Thorac Surg. 1992 Jun; 53 (6): 1080–1090.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Portner PM, Oyer PE, Pennington DG, Baumgartner WA, Griffith BP, Frist WR et al. Implantable electrical left ventricular assist system: bridge to transplantation and the future. Ann Thorac Surg. 1989 Jan; 47 (1): 142–150.</mixed-citation><mixed-citation xml:lang="en">Portner PM, Oyer PE, Pennington DG, Baumgartner WA, Griffith BP, Frist WR et al. Implantable electrical left ventricular assist system: bridge to transplantation and the future. Ann Thorac Surg. 1989 Jan; 47 (1): 142–150.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Готье СВ, Иткин ГП, Шемакин СЮ, Саитгареев РШ, Попцов ВН, Захаревич ВМ и др. Первый опыт клинического применения отечественного аппарата вспомогательного кровообращения на базе имплантируемого осевого насоса для двухэтапной трансплантации сердца. Вестник трансплантологии и искусственных органов. 2013; 15 (3): 92–101. doi: 10.15825/1995-1191-2013-3-92-101.</mixed-citation><mixed-citation xml:lang="en">Gautier SV, Itkin GP, Shemakin SYu, Saitgareev RSh, Poptsov VN, Zakharevich VM et al. The first experience in clinical application of domestic circulatory support device on basis of implantable axial pump for two stage heart transplantation. Russian Journal of Transplantology and Artificial Organs. 2013; 15 (3): 92–101. [In Russ, English abstract]. doi: 10.15825/1995-1191-2013-3-92-101.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Rogers JG, Aaronson KD, Boyle AJ, Russell SD, Milano CA, Pagani FD et al. Continuous flow left ventricular assist device improves functional capacity and quality of life of advanced heart failure patients. J Am Coll Cardiol. 2010 Apr 27; 55 (17): 1826–1834.</mixed-citation><mixed-citation xml:lang="en">Rogers JG, Aaronson KD, Boyle AJ, Russell SD, Milano CA, Pagani FD et al. Continuous flow left ventricular assist device improves functional capacity and quality of life of advanced heart failure patients. J Am Coll Cardiol. 2010 Apr 27; 55 (17): 1826–1834.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Pagani FD, Miller LW, Russell SD, Aaronson KD, John R, Boyle AJ et al. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol. 2009 Jul 21; 54 (4): 312–321.</mixed-citation><mixed-citation xml:lang="en">Pagani FD, Miller LW, Russell SD, Aaronson KD, John R, Boyle AJ et al. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol. 2009 Jul 21; 54 (4): 312–321.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Kirklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA et al. Second INTERMACS annual report. More than 1,000 primary left ventricular assist device implants. J Heart Lung Transplant. 2010 Jan; 29 (1): 1–10.</mixed-citation><mixed-citation xml:lang="en">Kirklin JK, Naftel DC, Kormos RL, Stevenson LW, Pagani FD, Miller MA et al. Second INTERMACS annual report. More than 1,000 primary left ventricular assist device implants. J Heart Lung Transplant. 2010 Jan; 29 (1): 1–10.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Stevenson LW, Kormos RL. Mechanical cardiac support 2000: current applications and future trial design. J Heart Lung Transpl. 2001 Jan; 20 (1): 1–38.</mixed-citation><mixed-citation xml:lang="en">Stevenson LW, Kormos RL. Mechanical cardiac support 2000: current applications and future trial design. J Heart Lung Transpl. 2001 Jan; 20 (1): 1–38.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Иткин ГП, Филатов ИА, Дозоров КН, Адаскин АВ. Косвенные методы определения расхода и напора роторных насосов для крови. Вестник трансплантологии и искусственных органов. 2015; 17 (1): 97–102. doi: 10.15825/1995-1191-2015-1-97-102.</mixed-citation><mixed-citation xml:lang="en">Itkin GP, Filatov IA, Dozorov KN, Adaskin AV. Indirect methods of measuring flоw rate and pressure drop of rotary blood pumps. Russian Journal of Transplantology and Artificial Organs. 2015; 17 (1): 97–102. [In Russ, English abstract]. doi: 10.15825/1995-1191-2015-1-97-102.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Ayre PJ, Lowell NH, Woodard JC. Non-invasive flow estimation in an implantable rotory pump: a study considering non-pulsatile and pulsatile flow. Phyiol Meas. 2003 Feb; 24 (1): 179–189.</mixed-citation><mixed-citation xml:lang="en">Ayre PJ, Lowell NH, Woodard JC. Non-invasive flow estimation in an implantable rotory pump: a study considering non-pulsatile and pulsatile flow. Phyiol Meas. 2003 Feb; 24 (1): 179–189.</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Funakibo A, Ahmed S, Sakuma I, Fukui Y. Flow rate and pressure head estimation in a centrifugal blood pump. Artif Organs. 2002 Nov; 26 (11): 985–990.</mixed-citation><mixed-citation xml:lang="en">Funakibo A, Ahmed S, Sakuma I, Fukui Y. Flow rate and pressure head estimation in a centrifugal blood pump. Artif Organs. 2002 Nov; 26 (11): 985–990.</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Giridharan GA, Skliar M. Physiological Control of Blood Pumps Using Intrinsic Pump Parameters: a Computer Simulation Study. Artif Organs. 2006 Apr; 30 (4): 301–307.</mixed-citation><mixed-citation xml:lang="en">Giridharan GA, Skliar M. Physiological Control of Blood Pumps Using Intrinsic Pump Parameters: a Computer Simulation Study. Artif Organs. 2006 Apr; 30 (4): 301–307.</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Schima H, Trubel W, Moritz A, Wieselthaler G, Stohr HG, Thoma H et al. Noninvasive monitoring of rotary blood pumps: necessity, possibilities, and limitations. Artif Organs. 1992 Apr;16(2): 195–202.</mixed-citation><mixed-citation xml:lang="en">Schima H, Trubel W, Moritz A, Wieselthaler G, Stohr HG, Thoma H et al. Noninvasive monitoring of rotary blood pumps: necessity, possibilities, and limitations. Artif Organs. 1992 Apr;16(2): 195–202.</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Иткин ГП, Шемакин СЮ, Шохина ЕГ, Бурцев ВИ, Аврамов ПВ, Волкова ЕА и др. Результаты экспериментальных исследований на телятах первого отечественного имплантируемого осевого насоса. Вестник трансплантологии и искусственных органов. 2013; 15 (3): 49–58. doi: 10.15825/1995-1191-2013-3-49-58. 2</mixed-citation><mixed-citation xml:lang="en">Itkin GP, Shemakin SJu, Shokhina EG, Burcev VI, Avramov PV, Volkova EA et al. The first domestic implantable axial flow pump: results of experimental studies in calves. Russian Journal of Transplantology and Artificial Organs. 2013; 15 (3): 49–58. [In Russ, English abstract]. doi: 10.15825/1995-1191-2013-3-49-58.</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Иткин ГП, Бучнев АС, Кулешов АП, Дробышев АА, Сырбу АИ. Гидродинамический стенд для исследования педиатрических систем вспомогательного кровообращения. Медицинская техника. 2022; 1: 5–8. doi: 10.1007/s10527-022-10156-9.</mixed-citation><mixed-citation xml:lang="en">Itkin GP, Buchnev AS, Kuleshov AP, Drobyshev AA, Syrbu AI. A hydrodynamic bench for testing pediatric circulatory support devices. Biomedical Engineering. 2022; 56 (1): 6–10. [In Russ, English abstract]. doi: 10.1007/s10527-022-10156-9.</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Maher TR, Butler KC, Poirier VL, Gernes DB. HeartMate left ventricular assist devices: a multigeneration of implanted blood pumps. Artif Organs. 2001 May; 25 (5): 422–426.</mixed-citation><mixed-citation xml:lang="en">Maher TR, Butler KC, Poirier VL, Gernes DB. HeartMate left ventricular assist devices: a multigeneration of implanted blood pumps. Artif Organs. 2001 May; 25 (5): 422–426.</mixed-citation></citation-alternatives></ref><ref id="cit24"><label>24</label><citation-alternatives><mixed-citation xml:lang="ru">Owens WR, Bryant R 3rd, Dreyer WJ, Price JF, Morales DL. Initial Clinical Experience with the HeartMate II Ventricular Assist System in a Pediatric Institution. Artif Organs. 2010 Jul; 34 (7): 600–603.</mixed-citation><mixed-citation xml:lang="en">Owens WR, Bryant R 3rd, Dreyer WJ, Price JF, Morales DL. Initial Clinical Experience with the HeartMate II Ventricular Assist System in a Pediatric Institution. Artif Organs. 2010 Jul; 34 (7): 600–603.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
