<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">vtio</journal-id><journal-title-group><journal-title xml:lang="ru">Вестник трансплантологии и искусственных органов</journal-title><trans-title-group xml:lang="en"><trans-title>Russian Journal of Transplantology and Artificial Organs</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1995-1191</issn><publisher><publisher-name>Academician V.I.Shumakov National Medical Research Center of Transplantology and Artificial Organs", Ministry of Health of the Russian Federation</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.15825/1995-1191-2020-2-117-124</article-id><article-id custom-type="elpub" pub-id-type="custom">vtio-1192</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Трансплантация сердца и вспомогательное кровообращение</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>Heart Transplantation and Assisted Circulation</subject></subj-group></article-categories><title-group><article-title>Гидродинамическая эффективность бесшовного протеза клапана сердца</article-title><trans-title-group xml:lang="en"><trans-title>Hydrodynamic performance of a novel suturelessprosthetic aortic valve</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Клышников</surname><given-names>К. Ю.</given-names></name><name name-style="western" xml:lang="en"><surname>Klyshnikov</surname><given-names>K. Yu.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Клышников Кирилл Юрьевич</p><p>Адрес: 650002, Кемерово, Сосновый б-р., д. 6. Тел. (923) 516-68-66.</p></bio><bio xml:lang="en"><p>Kirill Klyshnikov</p><p>Address: 6, Sosnovy Boulevard, Kemerovo, 650002, Russian Federation. Tel. (923) 516-68-66</p></bio><email xlink:type="simple">KlyshnikovK@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Овчаренко</surname><given-names>Е. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Ovcharenko</surname><given-names>E. A.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Кудрявцева</surname><given-names>Ю. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Kudryavtseva</surname><given-names>Yu. A.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Барбараш</surname><given-names>Л. С.</given-names></name><name name-style="western" xml:lang="en"><surname>Barbarash</surname><given-names>L. S.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ФГБНУ «Научно-исследовательский институт комплексных проблем сердечно-сосудистых заболеваний»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Research Institute for Complex Issues of Cardiovascular Diseases</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2020</year></pub-date><pub-date pub-type="epub"><day>12</day><month>07</month><year>2020</year></pub-date><volume>22</volume><issue>2</issue><fpage>117</fpage><lpage>124</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Клышников К.Ю., Овчаренко Е.А., Кудрявцева Ю.А., Барбараш Л.С., 2020</copyright-statement><copyright-year>2020</copyright-year><copyright-holder xml:lang="ru">Клышников К.Ю., Овчаренко Е.А., Кудрявцева Ю.А., Барбараш Л.С.</copyright-holder><copyright-holder xml:lang="en">Klyshnikov K.Y., Ovcharenko E.A., Kudryavtseva Y.A., Barbarash L.S.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://journal.transpl.ru/vtio/article/view/1192">https://journal.transpl.ru/vtio/article/view/1192</self-uri><abstract><p>Целью исследования стало гидродинамическое in vitro исследование разрабатываемого протеза клапана сердца II генерации, предназначенного для проведения вмешательства по типу «протез в протез». Материал и методы. Опытные образцы разрабатываемого изделия исследовали в условиях имитации физиологического режима работы сердца на установке пульсирующего потока Vivitro Labs (Канада) в сравнительном аспекте с клиническими коммерческими биопротезами клапана аорты «ЮниЛайн» (Россия). Образцы испытывали при имитации процедуры повторного бесшовного репротезирования. Результаты. Разрабатываемая конструкция продемонстрировала удовлетворительные характеристики – для всех случаев «имплантации» с позиции среднего транспротезного градиента (6,1–11,1 мм рт. ст.) и эффективно площади отверстия (1,60–1,81 см2 ). Анализ показателя фракции регургитации позволил определить оптимальные типоразмеры для имплантации по типу «протез в протез», которые впоследствии лягут в основу сайзинга при подборе необходимого типоразмера для реимплантации. Качественный анализ работы створчатого аппарата продемонстрировал наличие незначительной асимметрии для ряда протезов – как «ЮниЛайн», так и экспериментального протеза, в случае несоответствия типоразмеров при имитации процедуры «протез в протез». Заключение. Проведенные испытания демонстрируют состоятельность разрабатываемой конструкции с позиции гидродинамической эффективности и определяют основные закономерности подбора протеза для реимплантации относительно первичного клапана.</p></abstract><trans-abstract xml:lang="en"><p>The aim of the study was an in vitro hydrodynamic study of the developed prosthetic heart valve of the second generation, designed to carry out an implantation using «valve-in-valve» method. Material and methods. Prototypes of the developed prosthesis were studied under simulated physiological conditions of the heart using a Vivitro Labs pulse duplicator (Canada) in a comparative aspect with «UniLine» clinical commercial aortic valve bioprosthesis (Russia). Samples were tested by simulating sutureless implantation procedure. Results. The developed valves showed satisfactory hydrodynamic characteristics – for all cases of «implantation» from the position of the average trans-prosthetic gradient (6.1–11.1 mm Hg) and the effective orifice area (1.60–1.81 cm2 ). The analysis of the regurgitation fraction allowed us to determine the optimal sizes for implantation using «valvein-valve» method, which subsequently will form the basis of sizing guidelines for size selection. A qualitative analysis of the leaflet’s work demonstrated the presence of slight asymmetry for a number of prostheses – in case of mismatch of sizes when simulating «valve-in-valve» procedure. Conclusion. The tests demonstrate the viability of the developed design from the standpoint of hydrodynamic efficiency and determines the basic rules of selecting a prosthesis for reimplantation relative to the primary valve.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>гидродинамическая эффективность</kwd><kwd>протез клапана аорты</kwd><kwd>транспротезный градиент</kwd><kwd>эффективная площадь отверстия</kwd></kwd-group><kwd-group xml:lang="en"><kwd>hydrodynamic efficiency</kwd><kwd>aortic valve prosthesis</kwd><kwd>trans-prosthetic gradient</kwd><kwd>effective orifice area</kwd></kwd-group><funding-group><funding-statement xml:lang="ru">Работа выполнена в рамках фундаментальной темы НИИ КПССЗ № 0546-2015-0011 «Патогенетическое обоснование разработки имплантатов для сердечно-сосудистой хирургии на основе биосовместимых материалов, с реализацией пациенториентированного подхода с использованием математического моделирования, тканевой инженерии и геномных предикторов».</funding-statement></funding-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Бокерия ЛА, Гудкова РГ. Сердечно-сосудистая хирургия – 2015. Болезни и врожденные аномалии системы кровообращения [Текст]; Секция по сердечнососудистой хирургии ученого совета Министерства здравоохранения Российской Федерации [и др.]. М.: Изд-во НЦССХ им. А.Н. Бакулева РАМН, 2002–2015. 225 с.</mixed-citation><mixed-citation xml:lang="en">Bokeriya LA, Gudkova RG. Serdechno-sosudistaya khirurgiya – 2015. Bolezni i vrozhdennye anomalii sistemy krovoobrashcheniya [Tekst]; Sektsiya po serdechno-sosudistoy khirurgii uchenogo soveta Ministerstva zdravookhraneniya Rossiyskoy Federatsii [i dr.]. M.: Izd-vo NTsSSKh im. A.N. Bakuleva RAMN, 2002– 2015. 225.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Рогулина НВ, Одаренко ЮН, Кокорин СГ, Барбараш ЛС. Механические и биологические протезы в хирургии изолированного порока аортального клапана. Евразийский кардиологический журнал. 2016; 3: 42–43.</mixed-citation><mixed-citation xml:lang="en">Rogulina NV, Odarenko YuN, Kokorin SG, Barbarash LS. Mekhanicheskie i biologicheskie protezy v khirurgii izolirovannogo poroka aortal’nogo klapana. Evraziyskiy kardiologicheskiy zhurnal. 2016; 3: 42–43.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Одаренко ЮН, Кокорин СГ, Стасев АН, Рогулина НВ, Бураго АЮ, Барбараш ЛС. 25-летний опыт применения ксеноаортальных эпоксиобработанных биопротезов в хирургии митральных пороков. Евразийский кардиологический журнал. 2016; 3: 45–46.</mixed-citation><mixed-citation xml:lang="en">Odarenko YuN, Kokorin SG, Stasev AN, Rogulina NV, Burago AYu, Barbarash LS. 25-letniy opyt primeneniya ksenoaortal’nykh epoksiobrabotannykh bioprotezov v khirurgii mitral’nykh porokov. Evraziyskiy kardiologicheskiy zhurnal. 2016; 3: 45–46.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Кудрявцева ЮА, Насонова МВ, Акентьева ТН, Бураго АЮ, Журавлева ИЮ. Роль шовного материала в кальцификации кардиоваскулярных биопротезов. Комплексные проблемы сердечно-сосудистых заболеваний. 2013; 4: 22–27.</mixed-citation><mixed-citation xml:lang="en">Kudryavtseva YuA, Nasonova MV, Akent’eva TN, Burago AYu, Zhuravleva IYu. Rol’ shovnogo materiala v kal’tsifikatsii kardiovaskulyarnykh bioprotezov. Kompleksnye problemy serdechnososudistykh zabolevaniy. 2013; 4: 22–27.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Nishimura RA, Otto CM, Bonow RO, Carabello BA, Erwin JP 3rd, Guyton RA et al. ACC/AHA Task Force Members. 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. Circulation. 2014; 129 (23): 2440–2492. doi: 10.1161/CIR.0000000000000029.</mixed-citation><mixed-citation xml:lang="en">Nishimura RA, Otto CM, Bonow RO, Carabello BA, Erwin JP 3rd, Guyton RA et al. ACC/AHA Task Force Members. 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. Circulation. 2014; 129 (23): 2440–2492. doi: 10.1161/CIR.0000000000000029.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Клышников КЮ, Овчаренко ЕА, Кудрявцева ЮА, Барбараш ЛС. Репротезирование клапанов сердца по методике «протез-в-протез». Российский кардиологический журнал. 2016; 11 (139): 73–80.</mixed-citation><mixed-citation xml:lang="en">Klyshnikov KYu, Ovcharenko EA, Kudryavtseva YuA, Barbarash LS. Reprotezirovanie klapanov serdtsa po metodike «protez-vprotez». Rossiyskiy kardiologicheskiy zhurnal. 2016; 11 (139): 73–80. doi: 10.15829/1560-4071-2016-11-73-80.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Balsam LB, Grossi EA, Greenhouse DG, Ursomanno P, Deanda A, Ribakove GH et al. Reoperative valve surgery in the elderly: predictors of risk and long-term survival. Ann Thorac Surg. 2010; 90 (4): 1195–1200. doi: 10.1016/j.athoracsur.2010.04.057.</mixed-citation><mixed-citation xml:lang="en">Balsam LB, Grossi EA, Greenhouse DG, Ursomanno P, Deanda A, Ribakove GH et al. Reoperative valve surgery in the elderly: predictors of risk and long-term survival. Ann Thorac Surg. 2010; 90 (4): 1195–1200. doi: 10.1016/j.athoracsur.2010.04.057.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Maganti M, Rao V, Armstrong S, Feindel CM, Scully HE, David TE. Redo valvular surgery in elderly patients. Ann Thorac Surg. 2009; 87 (2): 521–525. doi: 10.1016/j.athoracsur.2008.09.030.</mixed-citation><mixed-citation xml:lang="en">Maganti M, Rao V, Armstrong S, Feindel CM, Scully HE, David TE. Redo valvular surgery in elderly patients. Ann Thorac Surg. 2009; 87 (2): 521–525. doi: 10.1016/j.athoracsur.2008.09.030.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Имаев ТЭ, Комлев АЕ, Колегаев АС и др. Современное состояние проблемы транскатетерного репротезирования клапанов сердца по методике «клапанв-клапан». Consilium Medicum. 2016; 18 (5): 89–92.</mixed-citation><mixed-citation xml:lang="en">Imaev TE, Komlev AE, Kolegaev AS i dr. Sovremennoe sostoyanie problemy transkateternogo reprotezirovaniya klapanov serdtsa po metodike «klapan-v-klapan». Consilium Medicum. 2016; 18 (5): 89–92.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Regeer M, Merkestein L, de Weger A, Kamperidis V, van der Kley F, van Rosendael P et al. Left bundle branch block after sutureless, transcatheter, and stented biological aortic valve replacement for aortic stenosis. EuroIntervention. 2017; 12 (13): 1660–1666.</mixed-citation><mixed-citation xml:lang="en">Regeer M, Merkestein L, de Weger A, Kamperidis V, van der Kley F, van Rosendael P et al. Left bundle branch block after sutureless, transcatheter, and stented biological aortic valve replacement for aortic stenosis. EuroIntervention. 2017; 12 (13): 1660–1666.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Алекян БГ, Григорьян АМ, Стаферов АВ, Карапетян НГ. Рентгенэндоваскулярная диагностика и лечение заболеваний сердца и сосудов в Российской Федерации – 2017 год. Эндоваскулярная хирургия. 2018. 5 (2): 93–240.</mixed-citation><mixed-citation xml:lang="en">Alekyan BG, Grigor’yan AM, Staferov AV, Karapetyan NG. Rentgenendovaskulyarnaya diagnostika i lechenie zabolevaniy serdtsa i sosudov v Rossiyskoy Federatsii – 2017 god. Endovaskulyarnaya khirurgiya. 2018. 5 (2): 93–240. doi: 10.24183/2409- 4080-2018-5-2-93-240.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Барбараш ЛС, Клышников КЮ, Овчаренко ЕА, Стасев АН, Кокорин СГ. Патент на ПМ «Биологический протез для репротезирования клапанов сердца» № 156774. Опубл. 20.11.2015. Бюл. № 32: 11–13.</mixed-citation><mixed-citation xml:lang="en">Barbarash LS, Klyshnikov KYu, Ovcharenko EA, Stasev AN, Kokorin SG. Patent na PM «Biologicheskiy protez dlya reprotezirovaniya klapanov serdtsa» № 156774. Opubl. 20.11.2015. Byul. № 32: 11–13.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Овчаренко ЕА, Клышников КЮ, Саврасов ГВ, Глушкова ТВ, Барбараш ЛС. Исследование гидродинамической функции малоинвазивного биопротеза клапана аорты. Комплексные проблемы сердечнососудистых заболеваний. 2016; 5 (2): 39–45.</mixed-citation><mixed-citation xml:lang="en">Ovcharenko EA, Klyshnikov KYu, Savrasov GV, Glushkova TV, Barbarash LS. Issledovanie gidrodinamicheskoy funktsii maloinvazivnogo bioproteza klapana aorty. Kompleksnye problemy serdechno-sosudistykh zabolevaniy. 2016; 5 (2): 39–45.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Jeewandara TM, Wise SG, Ng MKC. Biocompatibility of Coronary Stents. Materials. 2014; 7 (2): 769–786. doi: 10.3390/ma7020769.</mixed-citation><mixed-citation xml:lang="en">Jeewandara TM, Wise SG, Ng MKC. Biocompatibility of Coronary Stents. Materials. 2014; 7 (2): 769–786. doi: 10.3390/ma7020769.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Butany J, Collins MJ. Analysis of prosthetic cardiac devices: a guide for the practising pathologist. J Clin Pathol. 2005 Feb; 58 (2): 113–124. Review.</mixed-citation><mixed-citation xml:lang="en">Butany J, Collins MJ. Analysis of prosthetic cardiac devices: a guide for the practising pathologist. J Clin Pathol. 2005 Feb; 58 (2): 113–124. Review.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Soares SJ, Feaver KR, Zhang W, Kamensky D, Aggarwal A, Sacks MS. Biomechanical Behavior of Bioprosthetic Heart Valve Heterograft Tissues: Characterization, Simulation, and Performance. Cardiovasc Eng Technol. 2016; 7 (4): 309–351. doi: 10.1007/s13239-016-0276-8.</mixed-citation><mixed-citation xml:lang="en">Soares SJ, Feaver KR, Zhang W, Kamensky D, Aggarwal A, Sacks MS. Biomechanical Behavior of Bioprosthetic Heart Valve Heterograft Tissues: Characterization, Simulation, and Performance. Cardiovasc Eng Technol. 2016; 7 (4): 309–351. doi: 10.1007/s13239-016-0276-8.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Avanzini A, Battini D. Structural analysis of a stented pericardial heart valve with leaflets mounted externally. Proc Inst Mech Eng H. 2014 Oct; 228 (10): 985–995. doi: 10.1177/0954411914552309. Epub 2014 Sep 23. PubMed PMID: 25252695.</mixed-citation><mixed-citation xml:lang="en">Avanzini A, Battini D. Structural analysis of a stented pericardial heart valve with leaflets mounted externally. Proc Inst Mech Eng H. 2014 Oct; 228 (10): 985–995. doi: 10.1177/0954411914552309. Epub 2014 Sep 23. PubMed PMID: 25252695.</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Martin C, Sun W. Simulation of long-term fatigue damage in bioprosthetic heart valves: effects of leaflet and stent elastic properties. Biomech Model Mechanobiol. 2014 Aug; 13 (4): 759–770. doi: 10.1007/s10237-013- 0532-x.</mixed-citation><mixed-citation xml:lang="en">Martin C, Sun W. Simulation of long-term fatigue damage in bioprosthetic heart valves: effects of leaflet and stent elastic properties. Biomech Model Mechanobiol. 2014 Aug; 13 (4): 759–770. doi: 10.1007/s10237-013- 0532-x.</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Marquez S, Hon RT, Yoganathan AP. Comparative hydrodynamic evaluation of bioprosthetic heart valves. J Heart Valve Dis. 2001; 10 (6): 802–811.</mixed-citation><mixed-citation xml:lang="en">Marquez S, Hon RT, Yoganathan AP. Comparative hydrodynamic evaluation of bioprosthetic heart valves. J Heart Valve Dis. 2001; 10 (6): 802–811.</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Базылев ВВ, Воеводин АБ, Россейкин ЕВ. Двухлетний опыт использования отечественного транскатетерного протеза аортального клапана «МЕДЛАБ». Бюллетень НЦССХ им. А.Н. Бакулева РАМН «Сердечно-сосудистые заболевания». 2017; 18 (S6): 131.</mixed-citation><mixed-citation xml:lang="en">Bazylev VV, Voevodin AB, Rosseykin EV. Dvukhletniy opyt ispol’zovaniya otechestvennogo transkateternogo proteza aortal’nogo klapana «MEDLAB». Byulleten’ NTsSSKh im. A.N. Bakuleva RAMN «Serdechno-sosudistye zabolevaniya». 2017; 18 (S6): 131.</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Bapat V. Technical pitfalls and tips for the valve-in-valve procedure. Ann Cardiothorac Surg. 2017; 6 (5): 541– 552. doi: 10.21037/acs.2017.09.13.</mixed-citation><mixed-citation xml:lang="en">Bapat V. Technical pitfalls and tips for the valve-in-valve procedure. Ann Cardiothorac Surg. 2017; 6 (5): 541– 552. doi: 10.21037/acs.2017.09.13.</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Reul RM, Ramchandani MK, Reardon MJ. Transcatheter Aortic Valve-in-Valve Procedure in Patients with Bioprosthetic Structural Valve Deterioration. Methodist Debakey Cardiovasc J. 2017; 13 (3): 132–141. doi: 10.14797/mdcj-13-3-132.</mixed-citation><mixed-citation xml:lang="en">Reul RM, Ramchandani MK, Reardon MJ. Transcatheter Aortic Valve-in-Valve Procedure in Patients with Bioprosthetic Structural Valve Deterioration. Methodist Debakey Cardiovasc J. 2017; 13 (3): 132–141. doi: 10.14797/mdcj-13-3-132.</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Dvir D, Webb JG, Bleiziffer S, Pasic M, Waksman R, Kodali S et al. Valve-in-Valve International Data Registry Investigators. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves. JAMA. 2014 Jul; 312 (2): 162–170. doi: 10.1001/jama.2014.7246.</mixed-citation><mixed-citation xml:lang="en">Dvir D, Webb JG, Bleiziffer S, Pasic M, Waksman R, Kodali S et al. Valve-in-Valve International Data Registry Investigators. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves. JAMA. 2014 Jul; 312 (2): 162–170. doi: 10.1001/jama.2014.7246.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
